{"product_id":"platinum-plus-5-para-patient-monitor","title":"PLATINUM PLUS - 5-PARA PATIENT MONITOR","description":"\u003ch2\u003e12.1\" Multi-Parameter Patient Monitor with Advanced Arrhythmia Analysis(Model-GPM1055P)\u003c\/h2\u003e\n\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e12.1\" Multi-Parameter Patient Monitor\u003c\/strong\u003e is a comprehensive monitoring solution designed for \u003cstrong\u003eadult, paediatric, and neonatal patients\u003c\/strong\u003e. Featuring a clear and colourful \u003cstrong\u003e12.1-inch TFT display\u003c\/strong\u003e, the monitor provides real-time monitoring of essential vital parameters including \u003cstrong\u003eECG, NIBP, SpO₂, RESP, Pulse Rate (PR), and Temperature (TEMP)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe monitor incorporates advanced \u003cstrong\u003eambulatory blood pressure monitoring technology\u003c\/strong\u003e with anti-motion capabilities, providing reliable NIBP measurements in various clinical environments. It supports \u003cstrong\u003e13 types of arrhythmia analysis\u003c\/strong\u003e and \u003cstrong\u003e15 types of drug dose calculations\u003c\/strong\u003e, helping healthcare professionals assess patient conditions and make informed clinical decisions.\u003c\/p\u003e\n\u003cp\u003eWith a built-in detachable rechargeable lithium battery offering approximately \u003cstrong\u003e4 hours of battery operation\u003c\/strong\u003e, the monitor is suitable for bedside use as well as patient transfers. It can store up to \u003cstrong\u003e8,000 groups of NIBP measurements\u003c\/strong\u003e, approximately \u003cstrong\u003e680 hours of trend data\u003c\/strong\u003e, and \u003cstrong\u003e200 alarm events\u003c\/strong\u003e for later review and analysis.\u003c\/p\u003e\n\u003cp\u003eThe device also provides multiple connectivity options including \u003cstrong\u003eHD, VGA, USB and Internet connector outputs\u003c\/strong\u003e, making it suitable for integration with external displays, data systems and hospital monitoring networks.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for \u003cstrong\u003eAdults, Paediatrics and Neonates\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClear and colourful \u003cstrong\u003e12.1-inch TFT display\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-parameter monitoring:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eECG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNIBP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpO₂\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRESP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulse Rate (PR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature (TEMP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced ambulatory blood pressure monitoring technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnti-motion technology for improved NIBP measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e13 types of arrhythmia analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e15 types of drug dose calculation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in detachable rechargeable lithium battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximately \u003cstrong\u003e4 hours of battery operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage of up to \u003cstrong\u003e8,000 groups of NIBP measurements\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to \u003cstrong\u003e680 hours of trend data and trend graphs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage and review of up to \u003cstrong\u003e200 alarm events\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple connectivity options: \u003cstrong\u003eHD, VGA, USB and Internet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulse modulation volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePacemaker detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple ECG gain and scan-speed options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApnoea alarm function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOver-pressure protection for NIBP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eECG Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Mode\u003c\/td\u003e\n\u003ctd\u003e3 Lead \/ 5 Lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Selection\u003c\/td\u003e\n\u003ctd\u003eI, II, III, aVR, aVL, aVF, V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain\u003c\/td\u003e\n\u003ctd\u003e×0.25, ×0.5, ×1, ×2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Speed\u003c\/td\u003e\n\u003ctd\u003e6.25 \/ 12.5 \/ 25 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeart Rate – Adult\u003c\/td\u003e\n\u003ctd\u003e15–300 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeart Rate – Paediatric\/Neonatal\u003c\/td\u003e\n\u003ctd\u003e15–350 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacemaker Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArrhythmia Analysis\u003c\/td\u003e\n\u003ctd\u003eUp to 13 types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eST Segment Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to +2.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eST Segment Accuracy Range\u003c\/td\u003e\n\u003ctd\u003e-0.8 to +0.8 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eST Segment Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mV or ±10%, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArrhythmia Analysis\u003c\/h3\u003e\n\u003cp\u003eThe monitor provides advanced arrhythmia analysis capable of identifying up to \u003cstrong\u003e13 types of arrhythmia patterns\u003c\/strong\u003e, supporting continuous ECG assessment and helping healthcare professionals identify abnormal cardiac rhythms.\u003c\/p\u003e\n\u003ch3\u003ePulse Rate (PR)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e30–250 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2 bpm or ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Modulation Volume\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eNIBP Specifications\u003c\/h3\u003e\n\u003cp\u003eThe monitor uses the \u003cstrong\u003eOscillometric Method\u003c\/strong\u003e for non-invasive blood pressure measurement and supports Manual, Automatic and Continuous measurement modes.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e10–270 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eOscillometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003eManual \/ Automatic \/ Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-Pressure Protection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Measurement Intervals\u003c\/td\u003e\n\u003ctd\u003e1 \/ 2 \/ 3 \/ 4 \/ 5 \/ 10 \/ 15 \/ 30 \/ 60 \/ 90 \/ 120 \/ 240 \/ 480 \/ 960 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNIBP Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 8,000 measurement groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpO₂ Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% for 70–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 0–69%\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Range\u003c\/td\u003e\n\u003ctd\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eDual Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRespiration (RESP)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eRA–LL Impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdult Range\u003c\/td\u003e\n\u003ctd\u003e0–120 breaths\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaediatric\/Neonatal Range\u003c\/td\u003e\n\u003ctd\u003e0–150 breaths\/min*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2 breaths\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApnoea Alarm\u003c\/td\u003e\n\u003ctd\u003e10–40 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Speed\u003c\/td\u003e\n\u003ctd\u003e6.25 \/ 12.5 \/ 25 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eThe original specification provided “0–15 0 breath\/min”; this has been interpreted as 0–150 breaths\/min.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eData Storage \u0026amp; Review\u003c\/h3\u003e\n\u003cp\u003eThe monitor provides extensive data storage for patient monitoring and retrospective review:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e8,000 groups\u003c\/strong\u003e of NIBP measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximately \u003cstrong\u003e680 hours\u003c\/strong\u003e of trend data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrend data and graphical trend display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to \u003cstrong\u003e200 alarm events\u003c\/strong\u003e available for review\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e13-type arrhythmia analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e15 types of drug dose calculation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnectivity\u003c\/h3\u003e\n\u003cp\u003eThe monitor supports multiple external connectivity and output options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHD output\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVGA output\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternet connector\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for integration with external monitoring and hospital information systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBattery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in detachable rechargeable lithium battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximately \u003cstrong\u003e4 hours of battery operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for bedside monitoring and patient transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClinical Applications\u003c\/h3\u003e\n\u003cp\u003eSuitable for use in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIntensive Care Units (ICU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency Departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperation Theatres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral Wards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Dependency Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePaediatric Departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeonatal Care Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecovery Rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClinics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNursing Homes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBedside Patient Monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Highlights\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e12.1\" Colour TFT Display | Adult, Paediatric \u0026amp; Neonatal Monitoring | ECG | NIBP | SpO₂ | RESP | PR | TEMP | 13-Type Arrhythmia Analysis | 15 Drug Dose Calculations | 8,000 NIBP Storage Groups | 680 Hours Trend Storage | 200 Alarm Events | Rechargeable Battery | HD | VGA | USB | Internet Connectivity\u003c\/strong\u003e\u003c\/p\u003e","brand":"Glamatic Pharmaceuticals","offers":[{"title":"Default Title","offer_id":46685423960261,"sku":null,"price":52000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/1193\/2869\/files\/1_6ed35c60-7e04-465e-9c52-3e5d2c25c27d.jpg?v=1786435489","url":"https:\/\/glamaticstore.com\/products\/platinum-plus-5-para-patient-monitor","provider":"Glamatic Pharmaceuticals ","version":"1.0","type":"link"}