{"product_id":"vertex-vega-6-0-fixed-x-ray-machine","title":"VERTEX VEGA 6.0 Fixed X-Ray Machine","description":"\u003ch1\u003eVERTEX VEGA 6.0 Fixed X-Ray Machine\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eModel: VEGA 6.0\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eProduct Category: High-Frequency Fixed X-Ray Machine\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower Output: 6.0 kW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAERB Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eVERTEX VEGA 6.0\u003c\/strong\u003e is a high-frequency fixed X-Ray machine designed for reliable and controlled radiographic imaging. The system features a \u003cstrong\u003eHuman Machine Interface\u003c\/strong\u003e, \u003cstrong\u003eHF Smart Generator\u003c\/strong\u003e, sleek design and a high-performance control panel. The brochure specifies \u003cstrong\u003eAERB Type Approval\u003c\/strong\u003e and compliance with \u003cstrong\u003eBIS IS 7620: Part-1\u003c\/strong\u003e safety requirements.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHuman Machine Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLightweight design\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHF Smart Generator\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSleek Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-performance control panel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAERB Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for improved image quality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVEGA 6.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Frequency Fixed X-Ray Machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 VAC ±10%\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.5 Ω max\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.0 meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6.0 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekVp Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40–120 kV in kV\/step\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekVp Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±5 kV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emAs Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1–250 mAs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emAs Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±10%\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammed\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower supply cable shall be plugged where both poles (L \u0026amp; N) are isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEarthing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEarthing N to G \u0026lt;5 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX-Ray Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStationary Anode\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFocal Spot Nominal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.6 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInherent Tube Filtration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.8 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15°\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHigh-Frequency Generator\u003c\/h2\u003e\n\u003cp\u003eThe VEGA 6.0 incorporates an \u003cstrong\u003eHF Smart Generator\u003c\/strong\u003e operating at an output frequency of \u003cstrong\u003e40 kHz\u003c\/strong\u003e. The generator provides a \u003cstrong\u003e6.0 kW power output\u003c\/strong\u003e with a selectable \u003cstrong\u003e40–120 kV\u003c\/strong\u003e range and \u003cstrong\u003e1–250 mAs\u003c\/strong\u003e range.\u003c\/p\u003e\n\u003cp\u003eThe system incorporates programmed overload protection and specified kVp\/mAs accuracy for controlled X-Ray exposure.\u003c\/p\u003e\n\u003ch2\u003eX-Ray Tube\u003c\/h2\u003e\n\u003cp\u003eThe system is specified with a \u003cstrong\u003estationary-anode X-Ray tube\u003c\/strong\u003e featuring:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFocal Spot:\u003c\/strong\u003e 2.6 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInherent Tube Filtration:\u003c\/strong\u003e 0.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Angle:\u003c\/strong\u003e 15°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHuman Machine Interface\u003c\/h2\u003e\n\u003cp\u003eThe VEGA 6.0 is equipped with a \u003cstrong\u003eHuman Machine Interface (HMI)\u003c\/strong\u003e and a high-performance control panel intended to provide convenient control of the X-Ray system and exposure parameters.\u003c\/p\u003e\n\u003cp\u003eThe brochure specifically highlights the control panel as a feature intended to \u003cstrong\u003eimprove image quality with high-performance control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eElectrical Requirements\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMains:\u003c\/strong\u003e 230 VAC ±10%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Frequency:\u003c\/strong\u003e 40 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Impedance:\u003c\/strong\u003e 1.5 Ω maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Output:\u003c\/strong\u003e 6.0 kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Cable:\u003c\/strong\u003e 5.0 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEarthing:\u003c\/strong\u003e N to G \u0026lt;5 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMains isolation:\u003c\/strong\u003e Both L \u0026amp; N poles isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSafety \u0026amp; Regulatory Standards\u003c\/h2\u003e\n\u003cp\u003eThe brochure specifies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Standard:\u003c\/strong\u003e BIS \u003cstrong\u003eIS 7620: Part-1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Requirement:\u003c\/strong\u003e \u003cstrong\u003eAERB Type Approval\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAERB Approved\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe VEGA 6.0 is intended as a fixed X-Ray imaging solution for clinical radiographic applications, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral Radiography\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHospital Radiology Departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostic Imaging Centres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoutine X-Ray Examinations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHospital Diagnostic Departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eVERTEX VEGA 6.0 | High-Frequency Fixed X-Ray Machine | 6.0 kW | HF Smart Generator | Human Machine Interface | 40 kHz Output Frequency | 40–120 kV | 1–250 mAs | ±5 kV kVp Accuracy | ±10% mAs Accuracy | Programmed Overload Protection | Stationary Anode X-Ray Tube | 2.6 mm Focal Spot | 0.8 mm Inherent Filtration | 15° Target Angle | 230 VAC ±10% | 50 Hz | AERB Type Approval | BIS IS 7620: Part-1 | High-Performance Control Panel\u003c\/strong\u003e\u003c\/p\u003e","brand":"Glamatic Pharmaceuticals","offers":[{"title":"Default Title","offer_id":46913283752133,"sku":null,"price":1585500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/1193\/2869\/files\/1_1458604e-156d-4e75-a8fe-62bed005e1d6.jpg?v=1789406826","url":"https:\/\/glamaticstore.com\/products\/vertex-vega-6-0-fixed-x-ray-machine","provider":"Glamatic Pharmaceuticals ","version":"1.0","type":"link"}