{"product_id":"volumetric-infusion-pump","title":"VOLUMETRIC INFUSION PUMP","description":"\u003ch2\u003eGlamatic GPV1108 – Volumetric Infusion Pump\u003c\/h2\u003e\n\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGlamatic GPV1108 Volumetric Infusion Pump\u003c\/strong\u003e is a reliable and precise infusion solution designed for controlled delivery of intravenous fluids and medications in hospitals and clinical environments. It provides accurate flow-rate control, extensive infusion volume settings and multiple safety features to support safe and consistent infusion therapy.\u003c\/p\u003e\n\u003cp\u003eThe pump offers an adjustable \u003cstrong\u003eflow rate from 1 mL\/h to 1,200 mL\/h\u003c\/strong\u003e, with flow-rate accuracy of \u003cstrong\u003e±5% after correct calibration\u003c\/strong\u003e and mechanical precision of \u003cstrong\u003e±2%\u003c\/strong\u003e. Its intelligent monitoring system continuously checks infusion conditions and provides audible and visual alarms for events such as occlusion, end of infusion, door opening, air bubbles, incorrect settings, low battery and AC power interruption.\u003c\/p\u003e\n\u003cp\u003eAn integrated \u003cstrong\u003eultrasonic bubble detector\u003c\/strong\u003e helps identify air bubbles in the infusion line, while adjustable occlusion pressure levels allow the device to respond appropriately to different infusion conditions. The built-in rechargeable lithium battery provides approximately \u003cstrong\u003e4 hours of backup operation\u003c\/strong\u003e, helping maintain infusion during temporary power interruptions.\u003c\/p\u003e\n\u003cp\u003eWith a compact design, \u003cstrong\u003eIPX4 protection\u003c\/strong\u003e and Type CF applied-part classification, the GPV1108 is designed for dependable operation across a variety of clinical applications.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVolumetric Infusion Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel: \u003cstrong\u003eGPV1108\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBrand: \u003cstrong\u003eGlamatic\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for hospital and clinical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable flow rate from \u003cstrong\u003e1–1,200 mL\/h\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlow-rate accuracy: \u003cstrong\u003e±5% after correct calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical precision: \u003cstrong\u003e±2%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable total infusion volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKVO function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree-level adjustable occlusion alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltrasonic air-bubble detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAudible and visual alarm system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHuman voice alarm prompts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnd-of-infusion detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoor-open alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir-bubble alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWrong-setting alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-battery alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC power interruption alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in rechargeable lithium battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximately \u003cstrong\u003e4 hours battery backup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and lightweight design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIPX4 protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType CF classification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInfusion Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate\u003c\/td\u003e\n\u003ctd\u003e1–1,200 mL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin ±5% after correct calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Precision\u003c\/td\u003e\n\u003ctd\u003eWithin ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Rate\u003c\/td\u003e\n\u003ctd\u003e100–1,000 mL\/h, 100 mL\/h step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Infusion Volume\u003c\/td\u003e\n\u003ctd\u003e1–9,999 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfusion Volume Setting\u003c\/td\u003e\n\u003ctd\u003e0.1–9,999.9 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKVO Rate\u003c\/td\u003e\n\u003ctd\u003e1–5 mL\/h, 1 mL\/h step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOcclusion Pressure\u003c\/h3\u003e\n\u003cp\u003eThe GPV1108 provides three adjustable occlusion alarm levels to accommodate different infusion requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm Level\u003c\/th\u003e\n\u003cth\u003ePressure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh\u003c\/td\u003e\n\u003ctd\u003e800 ± 200 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd\u003e500 ± 100 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow\u003c\/td\u003e\n\u003ctd\u003e300 ± 100 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eApproximate pressure equivalents:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh:\u003c\/strong\u003e 106.7 ± 26.7 kPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMedium:\u003c\/strong\u003e 66.7 ± 13.3 kPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow:\u003c\/strong\u003e 40.7 ± 13.3 kPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAir Bubble Detection\u003c\/h3\u003e\n\u003cp\u003eThe integrated \u003cstrong\u003eultrasonic bubble detector\u003c\/strong\u003e monitors the infusion line for air bubbles.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eUltrasonic Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Sensitivity\u003c\/td\u003e\n\u003ctd\u003e≥25 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis provides an additional layer of safety by detecting air bubbles during infusion.\u003c\/p\u003e\n\u003ch3\u003eAlarm \u0026amp; Safety System\u003c\/h3\u003e\n\u003cp\u003eThe pump features an intelligent \u003cstrong\u003eaudible and visual alarm system\u003c\/strong\u003e, including human voice alarm prompts for important operating conditions.\u003c\/p\u003e\n\u003cp\u003eAlarms include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnd of infusion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOcclusion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoor open\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir bubbles in the infusion tube\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncorrect setting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC power interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOther system operating conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese alarms help healthcare professionals identify potential infusion issues promptly.\u003c\/p\u003e\n\u003ch3\u003ePower Supply \u0026amp; Battery\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Power Supply\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eInternal Rechargeable Li Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e≥1,600 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003eApproximately 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e18 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003eF1AL\/250V, 2 pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe internal rechargeable battery provides backup operation during temporary power interruptions.\u003c\/p\u003e\n\u003ch3\u003eOperating Conditions\u003c\/h3\u003e\n\u003cp\u003eThe GPV1108 is designed for operation under the following environmental conditions:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e+5°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e20–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure\u003c\/td\u003e\n\u003ctd\u003e86.0–106.0 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransport \u0026amp; Storage Conditions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +55°C*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e≤95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Based on the supplied manufacturer specification.\u003c\/p\u003e\n\u003ch3\u003eEquipment Classification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Classification\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eInternal Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplied Part\u003c\/td\u003e\n\u003ctd\u003eType CF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Classification\u003c\/td\u003e\n\u003ctd\u003eIPX4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 × 157 × 220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Glamatic GPV1108 is suitable for controlled infusion applications in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHospitals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntensive Care Units (ICU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral Wards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperation Theatres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency Departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePaediatric Departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeonatal Care\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClinics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNursing Homes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical Care Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedical and Surgical Departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Highlights\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGlamatic GPV1108 | Volumetric Infusion Pump | 1–1200 mL\/h Flow Rate | ±5% Flow Accuracy | ±2% Mechanical Precision | 1–9999 mL Infusion Volume | KVO 1–5 mL\/h | 3-Level Occlusion Alarm | Ultrasonic Bubble Detector | ≥25 µL Detection Sensitivity | Human Voice Alarm | End-of-Infusion Alarm | Door-Open Alarm | Low-Battery Alarm | 4-Hour Battery Backup | 100–240 V AC | IPX4 | Type CF | 1.8 kg Compact Design\u003c\/strong\u003e\u003c\/p\u003e","brand":"Glamatic Pharmaceuticals","offers":[{"title":"Default Title","offer_id":46685694001349,"sku":null,"price":27000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/1193\/2869\/files\/1_bedeb2ca-dff3-4c54-8e1c-b5dac171d373.jpg?v=1786444708","url":"https:\/\/glamaticstore.com\/products\/volumetric-infusion-pump","provider":"Glamatic Pharmaceuticals ","version":"1.0","type":"link"}