VOLUMETRIC INFUSION PUMP
VOLUMETRIC INFUSION PUMP
Share
Couldn't load pickup availability
Glamatic GPV1108 – Volumetric Infusion Pump
Product Description
The Glamatic GPV1108 Volumetric Infusion Pump is a reliable and precise infusion solution designed for controlled delivery of intravenous fluids and medications in hospitals and clinical environments. It provides accurate flow-rate control, extensive infusion volume settings and multiple safety features to support safe and consistent infusion therapy.
The pump offers an adjustable flow rate from 1 mL/h to 1,200 mL/h, with flow-rate accuracy of ±5% after correct calibration and mechanical precision of ±2%. Its intelligent monitoring system continuously checks infusion conditions and provides audible and visual alarms for events such as occlusion, end of infusion, door opening, air bubbles, incorrect settings, low battery and AC power interruption.
An integrated ultrasonic bubble detector helps identify air bubbles in the infusion line, while adjustable occlusion pressure levels allow the device to respond appropriately to different infusion conditions. The built-in rechargeable lithium battery provides approximately 4 hours of backup operation, helping maintain infusion during temporary power interruptions.
With a compact design, IPX4 protection and Type CF applied-part classification, the GPV1108 is designed for dependable operation across a variety of clinical applications.
Key Features
-
Volumetric Infusion Pump
-
Model: GPV1108
-
Brand: Glamatic
-
Designed for hospital and clinical applications
-
Adjustable flow rate from 1–1,200 mL/h
-
Flow-rate accuracy: ±5% after correct calibration
-
Mechanical precision: ±2%
-
Adjustable total infusion volume
-
KVO function
-
Three-level adjustable occlusion alarm
-
Ultrasonic air-bubble detection
-
Audible and visual alarm system
-
Human voice alarm prompts
-
End-of-infusion detection
-
Door-open alarm
-
Air-bubble alarm
-
Wrong-setting alarm
-
Low-battery alarm
-
AC power interruption alarm
-
Built-in rechargeable lithium battery
-
Approximately 4 hours battery backup
-
Compact and lightweight design
-
IPX4 protection
-
Type CF classification
Infusion Specifications
| Parameter | Specification |
|---|---|
| Flow Rate | 1–1,200 mL/h |
| Flow Rate Accuracy | Within ±5% after correct calibration |
| Mechanical Precision | Within ±2% |
| Pulse Rate | 100–1,000 mL/h, 100 mL/h step |
| Total Infusion Volume | 1–9,999 mL |
| Infusion Volume Setting | 0.1–9,999.9 mL |
| KVO Rate | 1–5 mL/h, 1 mL/h step |
Occlusion Pressure
The GPV1108 provides three adjustable occlusion alarm levels to accommodate different infusion requirements.
| Alarm Level | Pressure |
|---|---|
| High | 800 ± 200 mmHg |
| Medium | 500 ± 100 mmHg |
| Low | 300 ± 100 mmHg |
Approximate pressure equivalents:
-
High: 106.7 ± 26.7 kPa
-
Medium: 66.7 ± 13.3 kPa
-
Low: 40.7 ± 13.3 kPa
Air Bubble Detection
The integrated ultrasonic bubble detector monitors the infusion line for air bubbles.
| Parameter | Specification |
|---|---|
| Detection Method | Ultrasonic Wave |
| Detection Sensitivity | ≥25 µL |
This provides an additional layer of safety by detecting air bubbles during infusion.
Alarm & Safety System
The pump features an intelligent audible and visual alarm system, including human voice alarm prompts for important operating conditions.
Alarms include:
-
End of infusion
-
Occlusion
-
Door open
-
Air bubbles in the infusion tube
-
Incorrect setting
-
Low battery
-
AC power interruption
-
Other system operating conditions
These alarms help healthcare professionals identify potential infusion issues promptly.
Power Supply & Battery
| Parameter | Specification |
|---|---|
| AC Power Supply | 100–240 V AC |
| Frequency | 50/60 Hz |
| Battery | Internal Rechargeable Li Battery |
| Battery Capacity | ≥1,600 mAh |
| Battery Backup | Approximately 4 hours |
| Power Consumption | 18 VA |
| Fuse | F1AL/250V, 2 pcs |
The internal rechargeable battery provides backup operation during temporary power interruptions.
Operating Conditions
The GPV1108 is designed for operation under the following environmental conditions:
| Parameter | Specification |
|---|---|
| Ambient Temperature | +5°C to +40°C |
| Relative Humidity | 20–90% |
| Atmospheric Pressure | 86.0–106.0 kPa |
Transport & Storage Conditions
| Parameter | Specification |
|---|---|
| Ambient Temperature | -30°C to +55°C* |
| Relative Humidity | ≤95% |
*Based on the supplied manufacturer specification.
Equipment Classification
| Parameter | Specification |
|---|---|
| Equipment Classification | Class II |
| Power Supply | Internal Power Supply |
| Applied Part | Type CF |
| IP Classification | IPX4 |
Physical Specifications
| Parameter | Specification |
|---|---|
| Dimensions | 140 × 157 × 220 mm |
| Net Weight | Approximately 1.8 kg |
Applications
The Glamatic GPV1108 is suitable for controlled infusion applications in:
-
Hospitals
-
Intensive Care Units (ICU)
-
General Wards
-
Operation Theatres
-
Emergency Departments
-
Paediatric Departments
-
Neonatal Care
-
Clinics
-
Nursing Homes
-
Critical Care Units
-
Medical and Surgical Departments
Product Highlights
Glamatic GPV1108 | Volumetric Infusion Pump | 1–1200 mL/h Flow Rate | ±5% Flow Accuracy | ±2% Mechanical Precision | 1–9999 mL Infusion Volume | KVO 1–5 mL/h | 3-Level Occlusion Alarm | Ultrasonic Bubble Detector | ≥25 µL Detection Sensitivity | Human Voice Alarm | End-of-Infusion Alarm | Door-Open Alarm | Low-Battery Alarm | 4-Hour Battery Backup | 100–240 V AC | IPX4 | Type CF | 1.8 kg Compact Design